<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Interior Scaffolding FAQ - Metaltech</title>
	<atom:link href="https://www.metaltech.co/category/faq/interior-scaffolding-faq/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.metaltech.co</link>
	<description></description>
	<lastBuildDate>Wed, 06 Nov 2024 16:50:47 +0000</lastBuildDate>
	<language>en-CA</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>When assembling a Jobsite Series 6′ Baker (I-CISC) and its 39″ extension (I-ISEX4PPNCAS), do we have to install a guardrail (I-CISGRJP)?</title>
		<link>https://www.metaltech.co/faq/when-assembling-a-jobsite-series-6%e2%80%b2-baker-i-cisc-and-its-39%e2%80%b3-extension-i-isex4ppncas-do-we-have-to-install-a-guardrail-i-cisgrjp/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:35:01 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-CISC]]></category>
		<category><![CDATA[I-CISGRJP]]></category>
		<category><![CDATA[I-ISEX4PPNCAS]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3303</guid>

					<description><![CDATA[<p>Yes, a guardrail must be installed. Standards say that a guardrail is required if the platform height is 8′ or more for CSA standard and 10′ or more for ANSI &#38; OSHA standards (this value can change depending on the local standards). Metaltech recommends the use of a guardrail even for a I-CISC without its [&#8230;]</p>
<p>The post <a href="https://www.metaltech.co/faq/when-assembling-a-jobsite-series-6%e2%80%b2-baker-i-cisc-and-its-39%e2%80%b3-extension-i-isex4ppncas-do-we-have-to-install-a-guardrail-i-cisgrjp/">When assembling a Jobsite Series 6′ Baker (I-CISC) and its 39″ extension (I-ISEX4PPNCAS), do we have to install a guardrail (I-CISGRJP)?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>Yes</strong>, a guardrail must be installed.</p>



<p>Standards say that a guardrail is required if the platform height is 8′ or more for CSA standard and 10′ or more for ANSI &amp; OSHA standards (this value can change depending on the local standards).</p>



<p>Metaltech recommends the use of a guardrail even for a I-CISC without its extension, even if standards do not require it.</p><p>The post <a href="https://www.metaltech.co/faq/when-assembling-a-jobsite-series-6%e2%80%b2-baker-i-cisc-and-its-39%e2%80%b3-extension-i-isex4ppncas-do-we-have-to-install-a-guardrail-i-cisgrjp/">When assembling a Jobsite Series 6′ Baker (I-CISC) and its 39″ extension (I-ISEX4PPNCAS), do we have to install a guardrail (I-CISGRJP)?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can we stack Jobsite Series 6′ Baker (I-CISC)?</title>
		<link>https://www.metaltech.co/faq/can-we-stack-jobsite-series-6%e2%80%b2-baker-i-cisc/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:38:12 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-CISC]]></category>
		<category><![CDATA[I-CISO4]]></category>
		<category><![CDATA[I-CISGRJP]]></category>
		<category><![CDATA[I-BMSO4TT]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3305</guid>

					<description><![CDATA[<p>Yes, it is possible to stack up to three units one on top of the other. When stacking 2 units, a guardrail (I-CISGRJP) and the 14″ outriggers (I-CISO4) must be installed. When stacking 3 units, a guardrail (I-CISGRJP) and the 46″ outriggers (I-BMSO4TT) must be installed.</p>
<p>The post <a href="https://www.metaltech.co/faq/can-we-stack-jobsite-series-6%e2%80%b2-baker-i-cisc/">Can we stack Jobsite Series 6′ Baker (I-CISC)?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>Yes</strong>, it is possible to stack up to three units one on top of the other.</p>



<ul class="wp-block-list"><li>When stacking 2 units, a guardrail (I-CISGRJP) and the 14″ outriggers (I-CISO4) must be installed.</li><li>When stacking 3 units, a guardrail (I-CISGRJP) and the 46″ outriggers (I-BMSO4TT) must be installed.</li></ul><p>The post <a href="https://www.metaltech.co/faq/can-we-stack-jobsite-series-6%e2%80%b2-baker-i-cisc/">Can we stack Jobsite Series 6′ Baker (I-CISC)?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can the Jobsite Series 6′ Baker (I-CISC) be installed in stairways?</title>
		<link>https://www.metaltech.co/faq/can-the-jobsite-series-6%e2%80%b2-baker-i-cisc-be-installed-in-stairways/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:40:36 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-CISC]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3307</guid>

					<description><![CDATA[<p>Yes, you just have to adjust the braces that support the platform, so it is horizontal. Each end can adjust separately every 2″ to be used in stairways.Remove casters when using on stairs.</p>
<p>The post <a href="https://www.metaltech.co/faq/can-the-jobsite-series-6%e2%80%b2-baker-i-cisc-be-installed-in-stairways/">Can the Jobsite Series 6′ Baker (I-CISC) be installed in stairways?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>Yes</strong>, you just have to adjust the braces that support the platform, so it is horizontal. Each end can adjust separately every 2″ to be used in stairways.<br>Remove casters when using on stairs.</p><p>The post <a href="https://www.metaltech.co/faq/can-the-jobsite-series-6%e2%80%b2-baker-i-cisc-be-installed-in-stairways/">Can the Jobsite Series 6′ Baker (I-CISC) be installed in stairways?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Does the scaffolding tower (I-T3CISC) come with platform with trap door?</title>
		<link>https://www.metaltech.co/faq/does-the-scaffolding-tower-i-t3cisc-come-with-platform-with-trap-door/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:42:01 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-T3CISC]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3309</guid>

					<description><![CDATA[<p>No, this tower contains platform without trapdoor.</p>
<p>The post <a href="https://www.metaltech.co/faq/does-the-scaffolding-tower-i-t3cisc-come-with-platform-with-trap-door/">Does the scaffolding tower (I-T3CISC) come with platform with trap door?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>No</strong>, this tower contains platform without trapdoor.</p><p>The post <a href="https://www.metaltech.co/faq/does-the-scaffolding-tower-i-t3cisc-come-with-platform-with-trap-door/">Does the scaffolding tower (I-T3CISC) come with platform with trap door?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>With which product the leveling jacks (I-IBSJP12H4) can be used?</title>
		<link>https://www.metaltech.co/faq/with-which-product-the-leveling-jacks-i-ibsjp12h4-can-be-used/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:43:14 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-BMSS]]></category>
		<category><![CDATA[I-CISCH1]]></category>
		<category><![CDATA[I-IBSJP12H4]]></category>
		<category><![CDATA[I-CISCDW]]></category>
		<category><![CDATA[I-CISCTP]]></category>
		<category><![CDATA[I-CISC]]></category>
		<category><![CDATA[I-CAISC]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3311</guid>

					<description><![CDATA[<p>These leveling jacks are used with interior scaffolding. They are compatible with: I-CISC I-BMSS I-CAISC I-CISCTP I-CISCAS I-CISCH1 I-CISCDW</p>
<p>The post <a href="https://www.metaltech.co/faq/with-which-product-the-leveling-jacks-i-ibsjp12h4-can-be-used/">With which product the leveling jacks (I-IBSJP12H4) can be used?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>These leveling jacks are used with interior scaffolding. They are compatible with:</p>



<ul class="wp-block-list"><li>I-CISC</li><li>I-BMSS</li><li>I-CAISC</li><li>I-CISCTP</li><li>I-CISCAS</li><li>I-CISCH1</li><li>I-CISCDW</li></ul><p>The post <a href="https://www.metaltech.co/faq/with-which-product-the-leveling-jacks-i-ibsjp12h4-can-be-used/">With which product the leveling jacks (I-IBSJP12H4) can be used?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Are the Jobsite Series 6′ Baker (I-CISC) &#038; the Jobsite Series Perry style (I-CISCPY) compatible?</title>
		<link>https://www.metaltech.co/faq/are-the-jobsite-series-6%e2%80%b2-baker-i-cisc-the-jobsite-series-perry-style-i-ciscpy-compatible/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:44:47 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-CISC]]></category>
		<category><![CDATA[I-CISCPY]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3313</guid>

					<description><![CDATA[<p>No, these two scaffolds are not compatible.</p>
<p>The post <a href="https://www.metaltech.co/faq/are-the-jobsite-series-6%e2%80%b2-baker-i-cisc-the-jobsite-series-perry-style-i-ciscpy-compatible/">Are the Jobsite Series 6′ Baker (I-CISC) & the Jobsite Series Perry style (I-CISCPY) compatible?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>No</strong>, these two scaffolds are not compatible.</p><p>The post <a href="https://www.metaltech.co/faq/are-the-jobsite-series-6%e2%80%b2-baker-i-cisc-the-jobsite-series-perry-style-i-ciscpy-compatible/">Are the Jobsite Series 6′ Baker (I-CISC) & the Jobsite Series Perry style (I-CISCPY) compatible?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can I use the rungs of the interior scaffolding to climb on the platform ?</title>
		<link>https://www.metaltech.co/faq/can-i-use-the-rungs-of-the-interior-scaffolding-to-climb-on-the-platform/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:47:28 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-BMSS]]></category>
		<category><![CDATA[I-CISC]]></category>
		<category><![CDATA[I-IMCN]]></category>
		<category><![CDATA[I-CAISC]]></category>
		<category><![CDATA[I-IMIS]]></category>
		<category><![CDATA[I-IRC]]></category>
		<category><![CDATA[I-BM6S]]></category>
		<category><![CDATA[I-CAIRC]]></category>
		<category><![CDATA[I-BM4S]]></category>
		<category><![CDATA[I-IMAC]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3315</guid>

					<description><![CDATA[<p>For the 6&#8242; Baker (I-CISC, I-BMSS, I-CAISC) &#38; 6&#8242; (I-IRC, I-BM6S) scaffoldings, yes you have to use the rungs of the frame. If the scaffolding has a platform with trapdoor, you have to climb from the inside of the scaffold. If the platform does not have a trapdoor, climb from the outside of the scaffold [&#8230;]</p>
<p>The post <a href="https://www.metaltech.co/faq/can-i-use-the-rungs-of-the-interior-scaffolding-to-climb-on-the-platform/">Can I use the rungs of the interior scaffolding to climb on the platform ?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>For the 6&#8242; Baker (I-CISC, I-BMSS, I-CAISC) &amp; 6&#8242; (I-IRC, I-BM6S) scaffoldings, yes you have to use the rungs of the frame. If the scaffolding has a platform with trapdoor, you have to climb from the inside of the scaffold. If the platform does not have a trapdoor, climb from the outside of the scaffold while respecting the “Maximum climbing distance” table in the assembly instruction. You can find the assembly instruction on our website under the product’s heading.</p>



<p>For the 6&#8242; (I-CAIRC), 5&#8242; (I-IMIS) and 4&#8242; (I-IMCN, I-BM4S, I-IMAC) scaffoldings, no you cannot use the rungs to climb up or down the structure. You have to use the platforms.</p><p>The post <a href="https://www.metaltech.co/faq/can-i-use-the-rungs-of-the-interior-scaffolding-to-climb-on-the-platform/">Can I use the rungs of the interior scaffolding to climb on the platform ?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can I remove the strap that is on the platform with trapdoor of the Jobsite Series 6′ Baker (I-CISCH1, I-CISCTP)?</title>
		<link>https://www.metaltech.co/faq/can-i-remove-the-strap-that-is-on-the-platform-with-trapdoor-of-the-jobsite-series-6%e2%80%b2-baker-i-cisch1-i-cisctp/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:53:12 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-CISCH1]]></category>
		<category><![CDATA[I-CISCTP]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3318</guid>

					<description><![CDATA[<p>No, the doors must always be closed when you are on the platform. By closing the doors, we avoid falls and it adds rigidity to the guardrail’s structure.</p>
<p>The post <a href="https://www.metaltech.co/faq/can-i-remove-the-strap-that-is-on-the-platform-with-trapdoor-of-the-jobsite-series-6%e2%80%b2-baker-i-cisch1-i-cisctp/">Can I remove the strap that is on the platform with trapdoor of the Jobsite Series 6′ Baker (I-CISCH1, I-CISCTP)?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>No</strong>, the doors must always be closed when you are on the platform. By closing the doors, we avoid falls and it adds rigidity to the guardrail’s structure.</p><p>The post <a href="https://www.metaltech.co/faq/can-i-remove-the-strap-that-is-on-the-platform-with-trapdoor-of-the-jobsite-series-6%e2%80%b2-baker-i-cisch1-i-cisctp/">Can I remove the strap that is on the platform with trapdoor of the Jobsite Series 6′ Baker (I-CISCH1, I-CISCTP)?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can I leave the guardrail’s (I-CISGRJP, I-CAISCGR, I-BMSGRJP) doors open?</title>
		<link>https://www.metaltech.co/faq/can-i-leave-the-guardrails-i-cisgrjp-i-caiscgr-i-bmsgrjp-doors-open/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:55:31 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-BMSGRJP]]></category>
		<category><![CDATA[I-CAISCGR]]></category>
		<category><![CDATA[I-CISGRJP]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3320</guid>

					<description><![CDATA[<p>No, the doors must always be closed when you are on the platform. By closing the doors, we avoid falls and it adds rigidity to the guardrail’s structure.</p>
<p>The post <a href="https://www.metaltech.co/faq/can-i-leave-the-guardrails-i-cisgrjp-i-caiscgr-i-bmsgrjp-doors-open/">Can I leave the guardrail’s (I-CISGRJP, I-CAISCGR, I-BMSGRJP) doors open?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>No</strong>, the doors must always be closed when you are on the platform. By closing the doors, we avoid falls and it adds rigidity to the guardrail’s structure.</p><p>The post <a href="https://www.metaltech.co/faq/can-i-leave-the-guardrails-i-cisgrjp-i-caiscgr-i-bmsgrjp-doors-open/">Can I leave the guardrail’s (I-CISGRJP, I-CAISCGR, I-BMSGRJP) doors open?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Is it possible to have bigger casters on the Jobsite Series 6′ Baker (I-CISC)?</title>
		<link>https://www.metaltech.co/faq/is-it-possible-to-have-bigger-casters-on-the-jobsite-series-6%e2%80%b2-baker-i-cisc/</link>
		
		<dc:creator><![CDATA[cristian]]></dc:creator>
		<pubDate>Wed, 23 Dec 2020 16:57:22 +0000</pubDate>
				<category><![CDATA[Interior Scaffolding FAQ]]></category>
		<category><![CDATA[FAQ]]></category>
		<category><![CDATA[I-CISC]]></category>
		<guid isPermaLink="false">https://www.metaltech.co/?post_type=faq&#038;p=3322</guid>

					<description><![CDATA[<p>Yes, the Jobsite Series 6′ Baker (I-CISCDW) have 6” casters. The Buildman 6′ Baker (I-BMSS) also have 6″ casters while having a higher capacity.</p>
<p>The post <a href="https://www.metaltech.co/faq/is-it-possible-to-have-bigger-casters-on-the-jobsite-series-6%e2%80%b2-baker-i-cisc/">Is it possible to have bigger casters on the Jobsite Series 6′ Baker (I-CISC)?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>Yes</strong>, the Jobsite Series 6′ Baker (I-CISCDW) have 6” casters. The Buildman 6′ Baker (I-BMSS) also have 6″ casters while having a higher capacity.</p><p>The post <a href="https://www.metaltech.co/faq/is-it-possible-to-have-bigger-casters-on-the-jobsite-series-6%e2%80%b2-baker-i-cisc/">Is it possible to have bigger casters on the Jobsite Series 6′ Baker (I-CISC)?</a> first appeared on <a href="https://www.metaltech.co">Metaltech</a>.</p>]]></content:encoded>
					
		
		
			</item>